About the Lab

Founded in September 2017, the EFD thermal characterization laboratory focuses on thermal characterization, thermal resistance analysis and reliability verification of semiconductors and electronic components. The lab holds TAF (Taiwan Accreditation Foundation) accreditation and original-manufacturer certification, and is one of the few distributors in the region operating its own independent thermal lab.

Measurable Devices

LEDs, logic ICs, diodes, discrete and module MOSFETs and IGBTs, SiC / GaN power devices, power modules, and any powered device with a measurable temperature-sensitive voltage.

TAF accreditation certificate of EFD thermal lab

Measurement Outputs

StandardResults
JEDEC JESD51-1 (electrical test method)Rth-jc, Rth-jb, Rth-ja, ΔTj, Zth thermal impedance, structure function, pulse thermal impedance, SOA
JEDEC JESD51-14 (transient dual interface)Junction-to-case thermal resistance, layer-by-layer thermal resistance, process yield inspection, process variation comparison
JEDEC JESD51-2ANatural-convection (still-air) Rth-ja measurement

Core Capabilities

1 · Semiconductor Thermal Characterization

Measuring how well heat escapes from the die.

  • Thermal resistance (Rth): junction-to-case and junction-to-ambient
  • Thermal transient analysis: non-destructive detection of internal package defects

2 · Automotive Module Lifetime Testing & Failure Analysis

Simulating real operating conditions to find weak points early.

  • Lifetime testing: AEC-Q101 / AQG 324 accelerated tests
  • Root cause analysis (RCA) with report support

Shared goal: precise measurement data that supports our customers' reliability design and quality verification.

Lab Equipment

  • Siemens Simcenter Micred T3Ster and T3Ster SI
  • Booster and power supplies: 150 V / 10 A and 11 V / 240 A
  • Thermostat temperature controller, 0–100 °C
  • Large liquid-cooled cold plate with Julabo chiller (400–500 W)
  • JEDEC-compliant still-air chamber
  • KeenusDesign PELNUS temperature-control platform with pressure fixture
T3Ster thermal test equipment

Request a Quote or Test Service

Tell us your device, test standard and schedule. Our engineers reply within 1–2 business days.